Raman spectroscopy — where it appears
Named by 5 essays across one field — each of them below, with the objects they name alongside it.
The distortion the ratio cannot see
A depolarisation ratio can be made into a structural probe: break a molecule's symmetry and a band fixed at three quarters comes off it by an amount that depends on the distortion. The question is whether two distortions the ratio can see separately might cancel into one it cannot. They do — and the cancellation is exact, at any size, because the blind direction is the one that keeps the symmetry.
One number was a direction too
The depolarisation probe is exactly blind to the totally symmetric direction, which suggests it reads the distortion's component outside that species. What is left is a plane, and over a circle in it the reading varies by a factor of 1.98 — smallest for one bond against another, largest for two bonds against one, repeating every sixty degrees.
The sum was flat all along
The depolarisation reading varies by a factor of two round a circle in the non-symmetric plane, and the anisotropy may belong to taking a maximum over four bands rather than to the physics. Summing the four instead gives a reading constant to four parts in ten thousand, against a maximum that varies by ninety-eight per cent.
What a linewidth leaves of the probe
The depolarisation probe had two limits. Read on each band it varies by a factor of two round a circle of distortions, and read on each pair blended it varies by two thirds of a per cent. A spectrum sits between them, and where it sits can now be computed. For boron trifluoride distorted by two hundredths of an ångström the direction survives until the line width approaches the bending pair's 2.8 cm⁻¹ splitting, not the stretching pair's 0.53. A pair drawn as one peak is still not read as its blend: that takes widths several times the splitting. And the resolution was always the easy half, because the splitting is first order in the distortion and the signal second.
The pyramid trades its pairs
Ammonia's depolarisation probe was expected to survive a wider line than boron trifluoride's, because both of its degenerate pairs are split more by the same distortion. It survives a narrower one. On the plane the bending pair carries the reading; on the pyramid the stretching pair does, thirty times over, and its splitting is the smaller of ammonia's two — so the direction halves at 2.6 cm⁻¹ instead of 3.5. What the pyramid keeps is the size. The contrast a measurement has to resolve is 178 times the plane's, and at a ratio precision of one per cent ammonia's direction becomes readable from 0.046 Å of distortion, where boron trifluoride's is unreadable at 0.16.
Named alongside it
The objects these essays reach for when they reach for this one.
Depolarisation ratioPolarisabilitySymmetry breakingDegeneracyModel limitIrreducible representationsNormal modeSelection rules